C18 Generator Set – 380 to 415 Volts

C18 Generator Set – 380 to 415 Volts

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Request a Quote

Maximum Rating715 kVA

Minimum Rating550 kVA

Emissions/Fuel StrategyLow Fuel, China Nonroad III Emis Stds

Voltage380 to 415 Volts

Frequency50 Hz

Speed1500 rpm

Duty CycleStandby, Prime

Engine ModelC18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

Bore5.71in

Stroke7.2in

Displacement1106.36in³

Compression Ratio14.5:1

AspirationAir to Air Aftercooled

Fuel SystemElectronic unit injection

Governor TypeAdemâ„¢A4

Length - Maximum162.4in

Width - Maximum78.3in

Height - Maximum75in

Standard

Turbocharger

Light duty air cleaner

Aftercooler core

Optional

Dual element air cleaner

Single element air cleaner

Standard

Air Cleaner

Standard

GCCP 1.2

Optional

Oil temperature displays

GCCP 1.5

Volt free contact

Protective devices: Earth fault relay - earth leageage ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - high fuel level alarm - Fuel level sensor

Local alarm modules

Remote annunciator modules

Local alarm horn

Standard

Exhaust flange outlet

Optional

Industrial, Residential, Critical Mufflers

Standard

Coolant drain line with valve

Caterpillar extended life coolant

Fan drive, battery charging alternator drive

Radiator and cooling fan with guard

Standard

Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use; shipped loose

Optional

Manifold and Turbocharger guard

Engine mounted muffler

8 and 10 inch elbow kits

8 and 10 inch GP flanges

10, 25 and 35 end in / end outmufflers

Standard

Secondary fuel filter

Fuel priming pump

Primary fuel filter with integral water separator

Standard

Standard 8 hour open set fuel tank

Optional

Integral - Duel wall fuel tank base

Manual fuel transfer pump

Fuel transfer system

Standard

IP23 Protection

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Matched to the performance and output characteristics of Cat engines

Optional

Anti-condensation heater

Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)

Oversize and premium generators

Standard

Segregated low voltage (AC/DC) wiring panel

Integrated Voltage Regulator

A frame generator - IP21 protection

Integrated Voltage Regulator

Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre

Power center, IP22

Matched to the performance and output characteristics of Cat engines

Optional

LC frame generator

Permanent magnet excitation

LC frame oversize generators

Space heaters

A frame oversize generator

A frame CIP generator

Ingress protection

LC frame CIP generator

Standard

Bus Bar

Optional

Circuit breakers, IEC compliant

Circuit breakers, UL listed

Standard

Cat Electronic Governor (ADEM A4)

Standard

GCCP Genset Controller

Standard

Lubricating oil

Oil drain valves

Optional

Manual sump pump

Standard

Rubber vibration isolators

Standard

Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines

Standard

24 Volt battery with rack and cables

Optional

Oversize batteries

Jacket water heater

Battery chargers

Heavy-duty starting system

Charging alternator

Standard

Engine and alternator pre-paint, Caterpillar yellow

Optional

Single or dual wall integral fuel tanks

UL 2200 package

Enclosures: sound attenuated, weather protective

EU Certificate of Conformance (CE)

Integral & sub-base UL listed dual wall fuel tanks

Narrow, Wide or Skid Base

The following options are based on regional and product configuration:

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

EEC Declaration of Conformity

CSA Certification

Sound attenuated, weather protective or high ambient weather protective enclosure

Automatic transfer switches (ATS)

Single or dual wall sub-base fuel tanks

Optional

3 Pole (IEC-100% rated) circuit breakers - Motorised

4 Pole (IEC-100% rated) circuit breakers - Motorised

Circuit breaker (IEC) auxiliary contacts

Pad-lockable circuit breaker device

3 Pole (IEC-100% rated) circuit breakers - Package mounted

4 Pole (IEC-100% rated) circuit breakers - Package mounted

Power terminal strip

Shunt trip for IEC breaker

Optional

Local & remote annunciator modules

Load share module

Remote monitoring software

EMCP (4.2) (4.3) (4.4)

Digital I/O module

Optional

Low coolant temperature alarm

Radiator duct flange

Optional

Sound attenuated enclosures

Optional

Jacket water heaters

5 Amp battery charger

Battery disconnect switch

CONTACT US

REQUEST A QUOTE

Complete this form to get a quote on the equipment you are interested in.

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    What You Get: A phone call from a rep or agent. A cost estimate for your machine or the project. An in-person consultation if necessary.