XQC1600

This rental generator set extends the Caterpillar line of rental power options improving efficiency and reduced owning and operating costs. The XQC1600 is equipped with an enhanced control system, designed to reduce installation and startup time. It is configured to switch between 50 and 60 Hz ratings at the press of a button. The control system features plant control programming and simulation, allowing complete system testing prior to generator set startup. Advanced product autonomy and monitoring capabilities reduce on-site manpower support requirements, minimize operator exposure to hazards, and permit site performance and maintenance data to be viewed, archived, and analyzed conveniently. Ideal in a stand-alone environment, combined with dozens of units in a power plant solution, or supporting utility systems worldwide.

Request a Quote

Rating1515 ekW (1893 kVA) Continuous

Frequency50/60 Hz

Voltage230 - 480 V

IPP Overload 50Hz1590 kW (1987 kVA)

IPP Rated 60Hz1705 kW (2131 kVA)

IPP Overload 60Hz1790 kW (2237 kVA)

EngineCat 3516C

FuelDiesel

Height - Without Chassis114in

Length - Without Chassis480in

Weight - Without Chassis, With Fuel, Lube Oil and Coolant70000lb

Width - Without Chassis97.5in

Standard

Heavy duty, dual element, PowerCore air cleaners with service indicators

Triple, primary fuel filters with water separators and bypass valves for on-the-fly filters changes

Secondary fuel filters on engine

Full flow oil filters with water-cooled oil cooler. Requires API CI-4 or higher lube oil

Lubricating oil system includes make-up system (113-L tank), oil drain lines routed to the engine rail, and quick evacuation system for faster, cleaner oil changes

Jacket water heater (9 kW, 3-phase 480VAC) with electric pump

Fuel cooler and electric fuel priming pump

Electronic differential pressure monitoring of all filters

Electronic ADEM A4 engine controls

Dual 24V electric starting motors

Standard

Double-bearing, 1844-Frame, SR-5 generator with anti-condensation space heaters (1.2 kW, 480V)

Brushless, form-wound, permanent magnet excited, thouree-phase, 4-lead design

Class H insulation operating at Class F temperature for extended life

Cat Integrated Voltage Regulator (Cat IVR)

Stator winding and bearing temperature detectors monitored by RTD module

Metallic mesh generator air inlet filters (2)

System 4 insulation protection

Standard

9-High stackable, CSC certified

Sound attenuated, hinged, radiator intake louvers

Sound attenuated package air intake louvers with foldable awnings

Five (5) lockable personnel doors with panic releases

Interior walls and ceilings insulated with 100 mm of acoustic paneling

Side bus bar access door with external access load cable connections

Shore power via distribution block connections for jacket water heater, battery charger, space heaters, and generator Anti-condensation Heaters

Six (6) DC lights with 60-min timer

Single-wall, 946-L (250gal) fuel tank; certified to BS799-5

Solenoid fuel fill control valve for automated filling

Sound attenuated to 75 dB(A) (50Hz) 81 dB(A) (60Hz) at 7m (23 ft)

Four (4) 1400-CCA, Group 4D, maintenance-free batteries, and 50A battery charger

Insulated exhaust silencer with 1.8m (6ft) stainless steel exhaust stack for increased site power density

Engine vibration isolators

Easy drain access to standard fluids

Standard Cat decals (Optional) and painted Cat Power Module White

Standard

Cooling package provides 49°C (120°F) ambient capability (50 & 60 Hz) at IPP Ratings @ 750m (2,460 ft)

Vertical, non-stacked radiator cores with dimpled fins and vertical air discharge

Variable frequency fan drive with smart fan control

Cat Extended Life Coolant (ELC)

Standard

EMCP 4.3 generator set controller

Automatic start/stop with cool down timer

Generator Protection features: 25, 32, 40, 50/51, 27/59, 81 O/U

AGC-4 provides voltage and frequency adjust, base load / PF / load sharing / synchouronizer, auto start / stop control & generator CB control, SCADA Interface (Ethernet), fuel level indications & alarms, fuel tank fuel transfer control

Reverse compatibility for interface to legacy power modules

100 kAIC, 4000A-Frame generator circuit breaker with LSIG trip unit

Multi-mode operation (Island (kW/kVAR sharing, Auto Mains Failure, Peak Shaving, Base Load Power, Export, zero power transfer, power management with multiple units)

Manual and automatic paralleling capability

Metering display: voltage, current, frequency, power factor, kW, WHM, kVAR, and synchouroscope

Standard

Factory testing of complete power module

CE Certified, NEMA, ISO and IEEE standards

O&M manuals

CONTACT US

REQUEST A QUOTE

Complete this form to get a quote on the equipment you are interested in.

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    What You Get: A phone call from a rep or agent. A cost estimate for your machine or the project. An in-person consultation if necessary.